This is the second unit to malfunction this way. I will keep you posted! Of course that means I'm only getting half the amount of heat that the unit should provide. The procedure for dis-assembling and servicing a Corona Inverter Heater can be found here. Posts. It is suppose to be rated very safe and efficient. You have to almost gut the unit. This whole warranty thing is not right! I am afraid it will burn the house down. This is the second unit to malfunction this way. There are a bunch of them out there with this problem. My Lifesmart renew 1500 was also turning itself off. If it looks like either of the following, then your heater is compatible and will work with this controller. By clicking Submit you are agreeing to the Complaints Board’s Terms and Conditions. These small changes can be caused by a build up of carbon or any other contaminates found inside a heating chamber. GB Energy Price Rises and Credit Not Refunded, Home Heating using paraffin Inverter heaters. This year when turned on got E1 code. We called and they sent us a part that truly would and should have a QUALIFIED electrician take care of. •Use only a three-prong, … 6. They did state that they have returned several units for the same problem. 2 work fine, but the third is a constant E1 code. has 48,479 members. Some of these documents are available in different languages. Heat exchanger temperature in the sensor zone is over 250°C Check the intake and outlet of the heating unit for unobstructed entry and exit of heated air. Eberspächer (UK) Ltd. You will see the thermo switch. Error code E01: Cause of issue: Flame sensor open circuit. The Internet is awash with super cheap air heaters that are sold via Ebay, Amazon, etc. 1. heater gave e1 error code unplug and plug in and worked until it quit working all together. The power goes off all together and then after a few minutes powers back on. Unplugging, rocking the unit (There's a unit "tilt" switch which they say may cause the problem.) A few nights ago, i was trying to run the heater and it was shutting itself off and while it was off, i raged on it grabbed it and shook it cursing it. If none of the above are applicable, you need a new thermostat and, for some units, a new power board. 3, Check the plug of flame sensor whether it is loose. The controller displays fault code E-03. If it has sat for awhile, like a few hours, it takes longer for it to happen but once it's warmed up, it goes back to shutting off after just a few minutes. Last time I had this type of issue the thermal regulator was replaced in 2010. i tried the "rocking the heater unplugged"...and HAHAHAHAHA...it worked!! WARNING: Risk of Electric Shock! Buy your thermostat from a U. S. manufacturer, as I did and it will solve this problem. Anyone know how to point the better business bureau at this product? Once this was done, I made sure that the flame rod was fully dry, before refitted it and putting the inverter heater back together again. Thanks. My husband is an electrician and has taken it completely apart to see what is causing this issue. (I have no idea why this fault code is needed, code 017 covers the problem! Occasionally, the inverter heater may also just display Error E1 right from the start, especially if several constant previous attempts have been made to reset and restart the heater. thanks alot but i use sand paper 400 and 120 , to clean flam rod and the problem not solved ,i try to touch the wires from 2 to 3 times and its working again, this problem happened only when its cold, Perhaps you need to consider replacing the flame rod, Your email address will not be published. Thus you can run out of fuel without actually being aware that you have. The fault cannot be restored automatically. Cross your fingers. 3) Check the pump dispenser. I did mine and it works fine now. The main power lights up. It isn't like there's different things going bad like bulbs burning out or fans smoking. • Remove connector from the metering pump, if the fault code 048 (interruption) is displayed the metering pump is defective –> replace metering pump. All rights reserved. Got the E-1 code after 4 minutes operation. Short-term fluctuation of the mains. Bought A Lifesmart 1500 - 6 element infared heater from Home Depot for under $100. When I received them I took the unit apart and changed both pieces and the unit ran fine for one winter. I will stick to the Edenpure heaters from now on. I bought my unit 2 years ago. the bad part can be bought on eBay. 03: Flame failure : 04: Supply voltage too high Chinese Diesel vehicle air heaters - Troubleshooting & Parts sales. Yes, I too have one good one, and one new one which is defective. I purchased a LifeSmart Heater model number LS1002HH13 in May of this year. Husband took it apart and it was a loose wire. Additional diagnosis needs to be performed since this fault code may be caused by a number of issues. If you allow your fuel to drop below a 1/4 tank it is possible that the fuel lines and fuel filter may back syphon in to the tank as it is below the level of the standpipe. i checked the connection on there and it's loose on the bottom connection. except the On/Off, in which case the run indicator will blink (or display fault code E1) and the buzzer will alarm. Runs all the time. I found a good video on utube that addressed the problem as a thermostat inside the unit that caused the issue. Remove the screws from the front exhaust plate and bend it up. Jim. Totally have the same problem. Unit went back to Home Depot. Was there a part number associated with this? It heats up, but won't shut off. 3. I told her that would be just like buying a new one. If you need more help with these or want me to repair your switch contact me [email protected] Hope this helps everyone. It requires getting inside the unit which gave detailed instructions, and testing the thermostat. I have decided to send them the picture of the melted wires and just buy a new one from another manufacturer. Can't seem to fine anything to do about it, it like it not even plug up!!! Unplugged the heater to find the plug end melted, the outlet had plastic melted on it from the plug. I opened it and unhooked the thermostat that's in front of the blower and hooked the wires together. Ur not nuts-it works! 4. – problem solved, and one working heater. Flame sensor open circuited. It is a easy fix with a little solder. This isn’t as bad as it sounds, because you can take the opportunity of cleaning out the chamber, and generally serving your Corona Heater at the same time. Save my name, email, and website in this browser for the next time I comment. Energy Prices Fall – Too little too late? Check as fault code 012. Has anyone received a satisfactory fix from the company for this issue or any issue they have had with this heater? On hold for support for over 45 minutes listening to horrible & loud music designed to make you hang up. Ionization current present even though there is no flame. I do suspect that the over temp sensor is the problem as ours will run most of the night on high without shutting down. part #ksd301a-a. Thanx to ? Drill the holes for the heater air inlet and heater exhaust, ensure that the hole are slightly oversize to allow the flex pipe fittings. Maybe a government or consumer protection investigation and recall may be in order. I then turned my attention to the various sensors inside the heater. The heater :must not be operated Danger of explosion and suffocation! Climate Control Systems Climate House, Yeoman Road Ringwood, Hampshire BH24 3FA Phone: +44 1425 480151 Fax: +44 1425 480152 On a footnote I have friends who purchased similiar looking units made by EdenPure and Bear who are having no issues whatsoever after several years of use. Fault description Possible cause Remedy Heater switches off automatically (= fault lock-out). These are very well copied such that original Eberspächer parts will fit perfectly. These heaters are generally manufactured via smaller assembly companies (there are approx. It seems to heat well but the rattle seems to indicate that something is loose or broken inside. And that  (in the majority of cases) , is how you solve the Corona Inverter Heater E1 Error. Shutting it off. Ok everyone I figured out the problem with theses. I have already replaced one unit where I bought it and the new one works fine. Use multimeter to check if the flame sensor is short circuited or open circuited. I am also going to send her a copy of all these problems that people have listed on here. Other posts say they do not answer the phone, and you have to pay for shipping if they repair it. does anyone know what could be wrong? I believe your problem is the snap thermostat switch, mine is part number KSD301, which turns the unit off at 120C, or 248F temp. We discuss the possibility that some manufacturers may build in an intentional fail feature so people will be placed in a position to buy another unit. Honestly, i think that was a fluke. Please answer the question as to heater use or your request to join will be declined. The other rod, at the opposite side is fed by a small single wire (on my heater it was a yellow wire), and held in place by a single screw. Please check your filter on the back of the unit to ensure it is clean of debris. breaker so its not getting enough power. The only way you would get even close to what the company says it does, is the temperature outside has to be above 60 degrees and the heater in a area no bigger than a 18 foot travel trailer. Warmda Fault and Error Codes. They have a quality problem on a part that retails for less than one dollar, that permits the unit to randomly turn itself off. I have cleaned the filter and checked the unit completely. Fri Apr 17, 2015 6:49 am NZMCA# 60322 Location. This sometimes resets the sensor. Worked fine for about a week and then started the E1 error code. Turned the unit off this morning to leave for work when my smoke detectors in the house goes off. The other causes are listed below and in … Do you have it on a GFCI? 2, Please use the multimeter to check the resistance of the flame sensor. I didn't realize it until i came across this complaint thing. Only difference is i've never seen an E1 error. ), all you are looking to do is to clean off the black deposits. If you are reading this, then the chances are that you are researching for information in respect of your Corona Inverter Heater constantly giving an E1 error code and refusing to ignite, there is a lot of information and discussion about the E1 errors on the internet, and many heater owners seem to suffer from it, however there hasn’t been a workable solution provided, until now. Mine does the same thing. Bought recently two Chinese 5kW cabin air heaters. The China thermostats have a problem with the ceramic, that is breaking down after a short period of use, causing the heater to become erratic, and even inoperable. Same as above. If your heater has a fault, the green indicator light will flash in a sequence unique to the heater fault. The pic showes them soldered. An open, candid message to AdBlocker users. Do you have it on an extension cord or surge protector? Un hook it and look at the pins that hold the push tabs on the switch. I have cleaned the filter and checked the unit completely. Purchased one of these 3 months ago. The loose pins need soldered fast look at my pic. I just bought this heater brand new, opened it and plugged it in. We used it in Tassie probably a dozen times and it worked 1st go every time. I got my heater given to me because it wouldn't. If you have some wire wool, this would be even better. I call them back with my concerns and my concerns of even having to try and fix this and I was told I can have them fix it but I have to pay shipping BOTH ways. Purchased from Ebay, it worked fine for first season but starting last winter and still this year, the same thing: heats for a few then shuts off. and will then timeout if not getting fuel with an E-08 code… This can sometimes cause power failures and give false positives. Is Gas Heating or Electric Heating Cheaper? First of all I washed the rod in standard dish detergent, followed by a blast of oven cleaner and an old toothbrush (in the UK I used Mr Muscle oven cleaner). Imported Diesel Heaters fault Codes by purdiegood Thu Jun 14, 2018 11:57 am ... 5KW Chinese Diesel Heater. If your Corona Inverter Heater is displaying E1 on its display panel, then check to ensure that the following symptoms are also present. Luckily my local Menard's has been extremely willing to exchange the units and are extremely helpful. Because the E1 error is experienced when the heater would normally pulse its internal pump, sending fuel to the atomizing chamber, then it is easy to believe that the E1 code … This companies and it's product should be band from all retail stores to sell it is garbage do not buy it. 5. Kero-241 Off Grid Portable Kerosene Heater Wick Burner, Using 4G or 5G Mobile Internet for Home Broadband, Zibro Heater Error Codes and Zibro Service Manual, Zibro LC-32 Inverter Heater cheapest price. Once re-assembled, the heater fired up as normal and voila! and if your cords getting hot its because you don't have it on its own. So that's what I've been doing to avoid the issue. Here's how I fixed it and now working fine. Used it for the last month, set at 64 degrees automatic shut off. Use multimeter to check if the flame sensor … Then if something happens again we have to pay shipping again! I had a problem with a Chinese Diesel heater with it shutting down or showing a Error 10 message. Once inside the atomisation chamber, you will see two metal rods close to the burner, one is supplied with a thick cable leading to a small plastic box – this is the ignitor. After troubleshooting online for about 30 minutes the rep took down my info and sent me a new power supply board and a thermostat. The Flame Rod, is located inside the Burner (atomisation) chamber, deep inside the heater, and so it requires the heater to be stripped down. If you read the manual, then very little user advice is provided other than that the E1 Error code is diagnosed as an Electrical Error, which requires further investigation by a Corona service agent, which can work out expensive, however I manage to diagnose and correct the Corona E1 Error myself for no cost, and this is the information which I am going to share with you here. © 2004-2021 ComplaintsBoard.com. Chances are they are loose. Flame goes out during operation. @Foozler Ken The effect of this is additional sooting, causing an exhaust blockage. Heater is without electric power. LifeSmart Comfort - life smart space heater, LifeSmart - life pro infrared quartz tower heater, View all 10 LifeSmart Comfort complaints & reviews. On the circuit board, I read the various connector designators and noticed that the heater contained a “Flame Rod”. I will also see if I can get some pictures and post them here. I rocked the unit and the damn thing works, These heaters are junk and probably a safety hazard. stay on. This is the Flame Rod, and to remove it, all you need to do is to gently slide off the connector terminal, and undo the screw holding of the bracket holding it in place. Then I am looking into whatever else I can possibly do to get someones awareness and attention!!! Although it is an indicator, it doesn’t necessarily mean it is overheating. I had same issue, had this for a year, keep getting e1 code, after 20 min. To eradicate this, do not allow your tank to go below 1/4 full. This could be due to a few things, and we suggest you review each of the following, and record your finding. My unit smells like something is burning awful smell, your [protected] Not taking any calls, the [protected] is always busy- what the hell is going on here. It should test closed until a temperature of 60 degrees C is reached. kind of scary. Most people throw it away, and buy another, but the part is $6.50 for 5 shipped off [email protected] There is a good video on y0utube showing how to disassemble and remove the KDS301, Well I'm back, my unit is now shutting down without displaying the error code. We had the same problem when we first purshused ours 2 years ago. Please connect the lead properly if it's loose. Same problem. possible fault Permanent Fault - False flame signal. 2. Because the flame rod, works entirely on changes in its resistance value being detected, then any small change outside of the normal parameters can cause false readings and incorrect operation of the electronics. I think I will have to exchange it for another unit. The best discriminator is to inspect the control board housed within the heater unit. it's a five dollar part. The people posting on this site have a legitimate complaint. The E1 error. Should be by itself due to safety precautions. The additive can cause your heater to flame out and issue a no fuel E08 warning. No combustion after starting and restarting. If this still occurs after the steps have been reviewed, we can isolate and address the issue if any: NeilV. Igot heater used at 2mths old, &in 1wk, E1 prob began. Last night I smelled this odd smell. Your email address will not be published. So, if your Corona inverter heater symptoms sound just like mine above, then read on and i’ll tell you how to correct and remove the error,  and restore your heater to fully working condition, without the time and expense of sending it to a Corona heater service agent. It appears to be a timed shutoff. Of course depending on the age of your inverter heater, and the wear on the flame rod, cleaning it may only be a temporary fix, and so it might be wise to contact a parts distributor and buy a replacement flame rod, ready to replace it, should the E1 error return at a later time. What does E1 mean on my Life Smart Infrared heater? Next, I gently sanded the metal rod with very fine grit sandpaper. I thought about it and we are concerned about this unit with the melted wires and I would never feel comfortable leaving it on! This is NOT A REPUTABLE COMPANY. 3. Solution: Check the overheat sensor, and reconnect the plug correctly. On Hydronic water heaters the code is for 10 overheats in succession). I will never purchase another lifesmart product in my life!! Getting a code E01, r=05 and LED light 11 & service light goes on. If you just hit the start button, the heater will engage the pump and start the heating process. Heard loud pop upon plugging in - figured an element blew but it started up. So, this was immediately the next prime suspect in my fault finding. It's sad how they want so much for a product that won't work for the price they want to sell it for. Hot tub has no power when plugged in it started tripping the dedicated electric box first. I have two heaters I bought the "New" 6 element heater after a few months the control panel stopped working. I don't mean it gets hot from the hot air it gets like, electrically hot like there is a lot of resistance there. I unplugged it, gently rocked it, front to back&side to side, 5-6Xs, &waited 5min.Its ran on high, 2+ wks, since, w/out issues. The units cost more, but seem to have better quality and customer service. •Use only diesel or kerosene to fuel the heater. But for now at least thats something. I managed to reach customer service and they had me to try a couple of different things. E1 error code and the thing is not even a yea rold and only used on cold days. The description on eBay was 12v 3kw Diesel Air Heater Tank Vent Duct Thermostat Silencer Caravan Motorhome. Heater does not switch on. Same model...Same problem...twice. Have not see anyone else with this problem but if smoke detector had not went off before leaving for work my house would have surly caught fire. I found the all to common E2 message is a loose thermostat wire it simply has to be reconnected (a very cheap clip was used to secure it to the board. (An error code on the digital controller will be “E” and a number. I have a unit ls69xxxxxx and it does the same thing, but it is about one year old. It didn't start to happen consistently until relatively recently. Alternative to Sky Multiscreen / Multiroom, Changing a Prepayment Meter to a Credit Meter, Dangerous 13A Plugs from China – Swegway Warning, Dimmable LED Light Bulb Lamps and Dimmer Switches. Just bought a second unit a few weeks back and it is working fine, but I think I am going to return it before I have ayn issues and get a better product. The first heater worked very well for half a day but regrettably now won’t fire up. I have 3 heaters from lifesmart. The E01. Our Heater kept shutting off as well. Stupidly ordered a newer model from Amazon just over $100 with free shipping. Typically, if the case is somehow obstructed from free airflow, the sensor may detect it is too hot and give the error code. A parking heater offers a cost effective and reliable way of heating a car interior and de-icing windows. Put unit on top of cabinets and ran it, still e1, took compressed air to fan, power board, front control panel, and everywhere else, problem solved. The unit works great. . I brought a new unit home yesterday and while carrying it into the house there was a loud rattle in the box. I would not recommend this heater to anyone, it does not heat what the company says it will. After a short time it turns itself back on with a beep. i notice only the one wire gets hot, the bottom one. Purchased a heater from you had it plugged in all of a sudden we look over and it's on fire could have killed us.